MINEPDED N°00103/D/MINEPDED/SG/DNC/SDNAV · 07/09/2022

Spill in progress?Response line · +237 655 65 08 48
Collecting a hydrocarbon-contaminated water sample, gloved hands over the basin

Case studies

Four treated cases, four analysis reports

Trials carried out in 2022, including the full-scale tests required by MINEPDED to obtain the approval.

Summary of results

Case treatedBeforeAfterReductionLaboratory
Hydrocarbon sludge treatmentAn international oil operator active in Cameroon282,704ppm3,151ppm−98.9 %HYDRAC
Oily sediment treatmentAn international oil operator active in Cameroon488,300ppm915ppm−99.8 %CPCI
Water decontamination after a spillAn international oil operator active in Cameroon22,540mg/l4.33mg/l−99.98 %HYDRAC
Waste water brought to standard before dischargeA gas operator active in Cameroon66mg/l< 1mg/l−> 98.5 %CPCI

The values above come from trials conducted in 2022 and predate routine operation of the process, whose acceptance criterion is set at 500 ppm TPH. Each figure is backed by an analysis report issued by a third-party laboratory.

Talk to IMAC

A site to remediate, a batch to treat, a quote to scope?

Describe the contamination, the estimated volume and your timescale, and we will come back with an approach and an order of magnitude.

Response line